Document IIF

Impact énergétique de l'échangeur de chaleur interne dans une armoire de congélation horizontale. Évaluation expérimentale des alternatives à faible PRP au R404A : R454C, R455A, R468A, R290 et R1270.

Energy impact of the Internal Heat Exchanger in a horizontal freezing cabinet. Experimental evaluation with the R404A low-GWP alternatives R454C, R455A, R468A, R290 and R1270.

Auteurs : CABELLO R., SÁNCHEZ D., LLOPIS R., ANDREU-NACHER A., CALLEJA-ANTA D.

Type d'article : Article de la RIF

Résumé

This work analyses the influence of the Internal Heat Exchan ger (IHX) on the energy performance of a vapor compression cycle associated with a freezing cabinet using different R404A low-GWP alternatives. Among them, the refrigerants R454C (GPW100=146), R455A (GPW100=146), R468A (GPW100=146), R290 (GPW100=5) and R1270 (GPW100=1.8) have been tested in a horizontal freezing cabinet maintaining a product target temperature of -20°C at the heat rejection temperatures of 20, 30 and 40°C. The results from tests show that the use of the IHX reduces energy consumption in all scenarios without significantly increasing the compressor's discharge temperature. For a test period of 16 h, the refrigerants that offer better reductions are R404A and R1270, followed by R455A, R290, R454C and R468A. The maximum energy saving is rated to 9.2% at the heat rejection temperature of 40°C, demonstrating that the enhancement of the IHX is better as higher the heat rejection conditions are.

Documents disponibles

Format PDF

Pages : 22-33

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Energy impact of the Internal Heat Exchanger in a horizontal freezing cabinet. Experimental evaluation with the R404A low-GWP alternatives R454C, R455A, R468A, R290 and R1270.
  • Identifiant de la fiche : 30029485
  • Langues : Anglais
  • Sujet : Alternatives aux HFC
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 137
  • Date d'édition : 05/2022
  • DOI : http://dx.doi.org/10.1016/j.ijrefrig.2022.02.007
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.

Liens


Voir d'autres articles du même numéro (22)
Voir la source